LPG VAPORIZER (KEV Series) Electric Heated and Water Bath Type

  • Electric heating with water bath type(Heating medium: water / Heat source: electric heater)
  • Design pressure : 1.77MPa(17.7bar)
  • Explosion proof : Class I, Division 1, Group D & Ex d IIB T4
  • Electric power : 220V 1P 50/60Hz, 220V 3P 50/60Hz, 380V 3P 50/60Hz, Etc
  • High quality and long-life electric heater
  • Safety devices
    • Prevention of liquid LPG overflow with reset by mechanical float
    • LPG Pressure safety valve : 1.76MPa(17.6bar)
    • Overheat protection by water thermal switch
    • Low water cut-off for heater by water level switch
  • Water temperature & Level gauge
  • LPG Temperature & Pressure gauge
  • Power status lamp to check power on-off condition
  • Electric power connections both the left side and right

FEATURES

  • Electric heating with water bath type(Heating medium: water / Heat source: electric heater)
  • Design pressure : 1.77MPa(17.7bar)
  • Explosion proof : Class I, Division 1, Group D & Ex d IIB T4
  • Electric power : 220V 1P 50/60Hz, 220V 3P 50/60Hz, 380V 3P 50/60Hz, Etc
  • High quality and long-life electric heater
  • Safety devices
    • Prevention of liquid LPG overflow with reset by mechanical float
    • LPG Pressure safety valve : 1.76MPa(17.6bar)
    • Overheat protection by water thermal switch
    • Low water cut-off for heater by water level switch
  • Water temperature & Level gauge
  • LPG Temperature & Pressure gauge
  • Power status lamp to check power on-off condition
  • Electric power connections both the left side and right

OPTIONS

  • Additional device for liquid LPG overflow prevention by solenoid valve and water thermal switch
    • In case of electric power outage and water low temperature
  • Control panel to check condition of vaporizer in the office
  • Explosion proof type lamp for solenoid valves open-close
  • Explosion proof type lamp for electric heaters on
  • Explosion proof type Emergency lamp for water high temperature
  • Explosion proof type selector switch for Vaporizer on-off
  • Stainless steel heating coil
  • Additional device for liquid LPG overflow prevention by LPG level LPG level switch

APPEARANCE

SPECIFICATION

Left/Right Scroll
MODEL NO. CAPACITY
(kg/hr)
HEATER
(kw/hr)
DIMENSIONS (mm) INLET
SIZE
OUTLET
SIZE
A B C D E F G
KEV-030 30 4.5 890 1055 1150 470 435 670 150 20A(3/4″) 20A(3/4″)
KEV-050 50 7.5 890 1055 1150 470 435 670 150 20A(3/4″) 20A(3/4″)
KEV-100 100 15 1040 1205 1300 470 435 670 150 20A(3/4″) 25A(1″)
KEV-150 150 22.5 1040 1220 1320 530 495 730 180 20A(3/4″) 25A(1″)
KEV-200 200 30 1030 1210 1310 670 635 880 180 20A(3/4″) 25A(1″)
KEV-300 300 22.5×2 1180 1360 1460 610 575 810 180 20A(3/4″) 25A(1″)
KEV-400 400 30×2 1100 1300 1400 730 695 985 240 25A(1″) 50A(2″)
KEV-500 500 25×3 1200 1400 1505 730 695 985 240 25A(1″) 50A(2″)
KEV-600 600 30×3 1300 1500 1605 790 755 1040 240 25A(1″) 50A(2″)
KEV-700 700 35×3 1300 1500 1605 950 900 1245 312.5 25A(1″) 50A(2″)
KEV-800 800 40×3 1360 1560 1665 950 900 1245 312.5 25A(1″) 50A(2″)
KEV-900 900 45×3 1430 1630 1760 1065 1015 1375 345 40A(1 1/2″) 80A(3″)
KEV-1000 1000 50×3 1500 1700 1830 1065 1015 1375 345 40A(1 1/2″) 80A(3″)
KEV-1100 1100 55×3 1600 1800 1930 1250 1200 1570 345 40A(1 1/2″) 80A(3″)
KEV-1200 1200 60×3 1650 1850 1930 1250 1200 1570 345 40A(1 1/2″) 80A(3″)

WEIGHT(KG)

Left/Right Scroll
MODEL NO. KEV-030 KEV-050 KEV-100 KEV-150 KEV-200 KEV-300 KEV-400 KEV-500 KEV-600 KEV-700 KEV-800 KEV-900 KEV-1000 KEV-1100 KEV-1200
Empty 95 100 126 160 206 232 310 370 450 600 650 755 790 930 980
Operation 168.5 168.5 212 274 406 410 550 635 825 1090 1170 1470 1545 2115 2225
Full 172.5 172.5 216 280 415 417 565 650 837 1107 1187 1492 1567 2137 2256